Clinical Evaluation of a Rebound Tonometer in Patients Who Underwent Penetrating Keratoplasty.
Jong Woo Kim, Ji Won Jung
Department of Ophthalmology, Inha University School of Medicine, Incheon, Korea. panch325@hanmail.net
전층각막이식을 시행한 안에서 리바운드 안압계의 임상적 유용성
김종우⋅정지원
인하대학교 의과대학 안과학교실
Correspondence:  Ji Won Jung,
Email: panch325@hanmail.net
Received: 3 May 2018   • Revised: 29 July 2018   • Accepted: 27 November 2018
Abstract
PURPOSE
To compare the measurements of the rebound tonometer (RT), Goldmann applanation tonometer (GAT) and noncontact tonometer (NCT) in patients who underwent penetrating keratoplasty (PKP), and to evaluate the reproducibility of the RT measurements. METHODS: This study included 19 PKP eyes and 28 normal eyes. We compared the intraocular pressure (IOP) measurements of the GAT and NCT with the RT in both groups using Spearman's correlation analysis and the Wilcoxon signed-rank test. The IOP, as measured with an RT in each group, was assessed with respect to reproducibility using the intraclass correlation coefficient (ICC). RESULTS: In normal eyes, there was no significant difference in the measurements obtained with the RT, GAT, and NCT (p > 0.050). In the patient group, the RT measurements were not significantly different from those of the GAT (p = 0.872), but they were significantly lower than those obtained with the NCT (p = 0.011). However, the RT measurements showed a relatively high correlation with those of the GAT and NCT (r = 0.770 and 0.879, respectively). The ICC of the RT was 0.986 for the PKP eye group and 0.961 for the normal eye group, both of which were highly reproducible. CONCLUSIONS: In PKP eyes, the measurements obtained with the RT showed a relatively high correlation with those of the GAT and NCT, and the repeatability of the RT measurements was high and similar to those for normal eyes. The RT can therefore be considered a useful method for measuring the IOP in PKP eyes.
Key Words: Goldmann applanation tonometer;Noncontact tonometer;Penetrating keratoplasty;Rebound tonometer


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
SKY 1004 Building #701
50-1 Jungnim-ro, Jung-gu, Seoul 04508, Korea
Tel: +82-2-583-6520    Fax: +82-2-583-6521    E-mail: kos08@ophthalmology.org                

Copyright © 2024 by Korean Ophthalmological Society.

Developed in M2PI

Close layer
prev next