Comparison of Nd:YAG Capsulotomy Rates between Hydrophobic and Hydrophilic Intraocular Lenses.
Mihyun Choi, Sun Young Kim, Mee Yon Lee, Young Chun Lee, Su Young Kim
Department of Ophthalmology and Visual Science, Uijeongbu St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Uijeongbu, Korea. cassiopeia-su@hanmail.net
소수성 인공수정체와 친수성 인공수정체의 Nd:YAG 레이저 후낭 절개술 시행률 비교
최미현⋅김선영⋅이미연⋅이영춘⋅김수영
가톨릭대학교 의과대학 의정부성모병원 안과 및 시과학교실
Abstract
PURPOSE
To compare neodymium-doped yttrium aluminum garnet (Nd:YAG) laser capsulotomy rates between hydrophobic and hydrophilic intraocular lenses. METHODS: The present retrospective study enrolled patients who received cataract surgery from a single surgeon between July 2006 to December 2009. Patients included in the study were implanted with SA60AT hydrophobic spherical intraocular lenses (Alcon, Fort Worth, TX, USA, 268 eyes) or I-FLEX hydrophilic spheric intraocular lenses (i-Medical®, Ophthalmic International Heidelberg GmbH, Mannheim, Germany, 331 eyes). The Nd:YAG capsulotomy rates and best-corrected visual acuity (BCVA) were compared between the two groups for 2 years after the operation. RESULTS: The mean follow-up period was 23.5 months and 22.6 months and the mean age was 68.6 years and 70.3 years in the SA60AT and I-FLEX groups, respectively. Follow-up periods were longer in the SA60AT group (p = 0.035), but ages were not significantly different between the two groups (p = 0.367). Nd:YAG laser capsulotomy rates were 6.3% in the SA60AT group and 11.2% in the I-FLEX group. Nd:YAG laser capsulotomy rates were significantly higher in the I-FLEX group (p = 0.020). BCVA before and after the Nd:YAG laser capsulotomy was not significantly different. CONCLUSIONS: Nd:YAG laser capsulotomy rates were higher in the I-FLEX hydrophilic spheric intraocular lens group than in the SA60AT hydrophilic spheric intraocular lens group. Adhesion between capsular bag and intraocular lens by bioadhesive character of hydrophobic acryl intraocular lens may contribute to the prevention of lens epithelial migration and posterior capsule opacification.
Key Words: Hydrophilic intraocular lens;Hydrophobic intraocular lens;Nd:YAG capsulotomy;Posterior capsule opacification


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
SKY 1004 Building #701
50-1 Jungnim-ro, Jung-gu, Seoul 04508, Korea
Tel: +82-2-583-6520    Fax: +82-2-583-6521    E-mail: kos08@ophthalmology.org                

Copyright © 2024 by Korean Ophthalmological Society.

Developed in M2PI

Close layer
prev next