Reliability Comparison of Rebound Tonometer at the Upright and Supine Position.
Kyoung Lae Kim, Ka Young Lee, Young Cheol Yoo
Department of Ophthalmology, Kangdong Sacred Heart Hospital, Hallym University College of Medicine, Seoul, Korea. demian7435@gmail.com
리바운드안압계로 안압측정 시 수직과 수평자세 측정값의 신뢰도 비교
김경래⋅이가영⋅유영철
Department of Ophthalmology, Kangdong Sacred Heart Hospital, Hallym University College of Medicine, Seoul, Korea
Abstract
PURPOSE
Rebound tonometer has been used to measure the intraocular pressure (IOP) in the supine as well as normal upright positions. We investigated the reliability of IOP measurements using the rebound tonometer in the upright and supine positions. METHODS: IOP was measured in 30 patients (60 eyes) with open-angle glaucoma who had no history of ocular surgery and no anterior segment pathology, in both the upright and supine positions using rebound tonometer (IcarePRO; Icare Finland Oy, Finland). The average IOP value after 6 measurements was recorded. We measured IOP repeatedly until 3 reliable values within normal limits of the measurement's variation were obtained. We calculated the intraclass correlation coefficient (ICC), coefficient of variation, and number of repeated measurements necessary to obtain 3 reliable IOP values in each position as measured by one examiner. RESULTS: ICC values for IOP measurements were 0.852 (95% confidence interval [CI], 0.784-0.903; p < 0.001) in the upright position and 0.684 (95% CI, 0.563-0.784; p < 0.027) in the supine position. Coefficient of variation was 8.7 +/- 0.1% in the upright position and 24.0 +/- 0.1% in the supine position. An average of 3.3 times of repeated measurements in the upright position and 6.2 times in the supine position were necessary to obtain 3 reliable IOP values within the normal range of standard deviation. CONCLUSIONS: When measuring IOP using the IcarePRO rebound tonometer, the measurement reliability was different between the upright and supine positions. Reproducibility of IOP measurements was lower in the upright than the supine position.
Key Words: Body position;Rebound tonometer;Reliability;Reproducibility


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
SKY 1004 Building #701
50-1 Jungnim-ro, Jung-gu, Seoul 04508, Korea
Tel: +82-2-583-6520    Fax: +82-2-583-6521    E-mail: kos08@ophthalmology.org                

Copyright © 2024 by Korean Ophthalmological Society.

Developed in M2PI

Close layer
prev next