Change in Corneal Biomechanical Parameters in Diabetes Mellitus.
Yeon Ggoch Park, Jin Young Rhew, Kyu Ryong Choi
The Institute of Ophthalmology and Optometry, Department of Ophthalmology, Ewha Womans University School of Medicine, Seoul, Korea. ckrey02@ewha.ac.kr
당뇨환자에서 각막생체역학인자의 변화
박연꽃⋅류진영⋅최규룡
이화여자대학교 의학전문대학원 안과학교실 이화시과학 연구센터
Abstract
PURPOSE
In this study, we examined the changes in corneal biomechanical parameters in patients with diabetes mellitus (DM). METHODS: Fifty patients with DM were divided into 2 subgroups, 25 diabetic patients with glycated hemoglobin (HbA1c < or = 7% and 25 diabetic patients with HbA1c > 7%) and compared with the eyes of 80 healthy subjects. Corneal biomechanical parameters were measured using ocular response analyzer (ORA). Differences in corneal biomechanical properties between healthy subjects and diabetic patients were compared. Additionally, differences in corneal biomechanical properties between diabetic patients with HbA1c < or = 7% and diabetic patients with HbA1c > 7% were compared. RESULTS: Corneal hysteresis, corneal resistance factor and central corneal thickness (CCT) were statistically significantly higher in patients with diabetes compared to healthy subjects. Goldmann tonometer, non-contact tonometer and Goldmann-correlated intraocular pressure (IOPg) were statistically significantly higher in patients with DM compared to healthy subjects, but corneal compensated IOP (IOPcc) was not statistically significantly different between healthy subjects and diabetic patients. However, corneal biomechanical parameters, which were statistically significantly different between healthy subjects and DM patients, were not statistically significantly different between diabetic patients with HbA1c < or = 7% and diabetic patients with HbA1c > 7%. CONCLUSIONS: Considering that corneal properties are different between diabetic patients and healthy subject, IOPcc measured with ORA is considered clinically useful for measuring IOP as it reflects CCT and biomechanical properties that should be revised. In diabetes, changes in corneal biomechanical properties depend on long-term glucose control rather than short-term glucose control.
Key Words: Central corneal thickness;Corneal hysteresis;Diabetes mellitus;Intraocular pressure;Ocular response analyzer


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
SKY 1004 Building #701
50-1 Jungnim-ro, Jung-gu, Seoul 04508, Korea
Tel: +82-2-583-6520    Fax: +82-2-583-6521    E-mail: kos08@ophthalmology.org                

Copyright © 2024 by Korean Ophthalmological Society.

Developed in M2PI

Close layer
prev next