J Korean Ophthalmol Soc > Volume 53(10); 2012 > Article
Journal of the Korean Ophthalmological Society 2012;53(10):1451-1457.
DOI: https://doi.org/10.3341/jkos.2012.53.10.1451    Published online October 15, 2012.
Clinical Outcomes of Aspheric 1-Piece (Tecnis(R) ZCB00) and 3-Piece (Tecnis(R) ZA9003) Aspheric Intraocular Lens for 12 Months.
Jong Hoon Park, Jae Hyung Kim, Joo Eun Lee, Jea Yong Kim, Myoung Joon Kim, Hung Won Tchah
Department of Ophthalmology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea. hwtchah@amc.seoul.kr
일체형 비구면 인공수정체 Tecnis? ZCB00과 삼체형 비구면 인공수정체 Tecnis? ZA9003의 앞방 깊이 변화 및 장기 안정성 비교
박종훈⋅김재형⋅이주은⋅김재용⋅김명준⋅차흥원
Department of Ophthalmology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
Abstract
PURPOSE
To evaluate the postoperative outcome of Tecnis(R) ZCB00 1-Piece acrylic intraocular lens (IOL), the new single piece, aspheric IOL until 12 months. METHODS: Sixty eyes undergone cataract surgery using two different IOLs; The Tecnis(R) ZCB00 1-Piece Acrylic IOL (30 eyes) and the Tecnis(R) ZA9003 3-Piece Acrylic IOL (30 eyes). Cataract surgery was performed in the same period. All complicated cases were excluded. Best corrected visual acuity (BCVA), refractive error, photopic and mesopic contrast sensitivity, total high order aberration, spherical aberration and anterior chamber depth were measured preoperatively and at 1, 6 and 12 months after surgery. RESULTS: There were no statistically significant differences between two groups in BCVA, refractive error, total high order aberration and spherical aberration all the time after surgery. Both groups have negative ocular spherical aberration until 12 months after surgery. 1-piece and 3-piece groups had different tendency in axial movement. But there were no statistically significant differences in anterior chamber depth measured at 1 week, 1, 6 and 12 months after surgery. There was no statistically significant difference in contrast sensitivity at 1, 6 and 12 months after surgery. CONCLUSIONS: The Tecnis(R) ZCB00 1-Piece acrylic intraocular lens (IOL) showed comparable clinical outcomes to the Tecnis(R) ZA9003 3-Piece acrylic intraocular lens (IOL) until 12 months after cataract surgery. 1-piece and 3-piece IOL group had different tendency in axial movement. However, refraction remained stable during 12 months after surgery. Mostly, both IOL groups had negative ocular spherical aberration during whole follow-up period.
Key Words: Single piece IOL and aspheric intraocular lens;ZCB00 1-Piece acrylic IOL


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
SKY 1004 Building #701
50-1 Jungnim-ro, Jung-gu, Seoul 04508, Korea
Tel: +82-2-583-6520    Fax: +82-2-583-6521    E-mail: kos08@ophthalmology.org                

Copyright © 2024 by Korean Ophthalmological Society.

Developed in M2PI

Close layer
prev next