J Korean Ophthalmol Soc > Volume 53(11); 2012 > Article
Journal of the Korean Ophthalmological Society 2012;53(11):1541-1548.
DOI: https://doi.org/10.3341/jkos.2012.53.11.1541    Published online November 15, 2012.
The Influence of a Silicone Tube on Tear Drainage in Patients with Healed Rhinostomy after Dacryocystorhinostomy.
Eun Hyung Cho, Su Youn Park, Koung Hoon Kook
Department of Ophthalmology, Ajou University School of Medicine, Suwon, Korea. drkook@ajou.ac.kr
눈물주머니코안연결술 후 창상회복이 완료된 환자에서 실리콘관이 눈물배출에 미치는 영향
조은형⋅박수연⋅국경훈
Department of Ophthalmology, Ajou University School of Medicine, Suwon, Korea
Abstract
PURPOSE
To evaluate the influence of a silicone tube on tear drainage in patients with a healed rhinostomy site after dacryocystorhinostomy. METHODS: The subjects of the present study included the patients for whom the removal of a silicone tube was performed after dacryocystorhinostomy for acquired nasolacrimal duct obstruction. The silicone tube was removed after the rhinostomy site was completely healed. The tear drainage function was evaluated using the fluorescein dye disappearance test at the following 3 time points: immediately before, immediately after, and 1 month after silicone tube removal. In addition, a Schirmer test was performed and tear break-up time was measured at each time point. To study the correlation between the measured values and subjective tearing symptoms, self-report questionnaires were given to each patient at his/her last visit. RESULTS: The 3 measured values showed no statistical difference between the 3 time points, immediately before, immediately after, and 1 month after silicone tube removal. When the patients were divided into groups according to their subjective symptomatic changes after silicone tube removal, no group showed statistically significant difference in the 3 measured values before, between, and after silicone tube removal. CONCLUSIONS: In patients with a healed rhinostomy site after dacryocystorhinostomy, the removal of the silicone tube did not induce a change of tear drainage function. Therefore, based on the results from the present study, a silicone tube may not have influence on tear drainage functions.
Key Words: Endonasal dacryocystorhinostomy;Silicone tube;Tear drainage function


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
#1001, Jeokseon Hyundai BD
130, Sajik-ro, Jongno-gu, Seoul 03170, Korea
Tel: +82-2-2271-6603    Fax: +82-2-2277-5194    E-mail: kos@ijpnc.com                

Copyright © 2024 by Korean Ophthalmological Society.

Developed in M2PI

Close layer
prev next