J Korean Ophthalmol Soc > Volume 53(12); 2012 > Article
Journal of the Korean Ophthalmological Society 2012;53(12):1756-1765.
DOI: https://doi.org/10.3341/jkos.2012.53.12.1756    Published online December 15, 2012.
The Clinical Results of Intacs(R) Ring Implantation by Manual Tunnel Creation in Patients with Keratoconus.
Eun Joo Kim, Sung Hyun Koo, Gwang Ja Lee, Kyoo Won Lee, Young Jeung Park
Cheil Eye Hospital, Daegu, Korea. eyepark9@dreamwiz.com
원추각막에서 수기 각막링 터널 생성을 이용한 인택스(Intacs)링 삽입술의 임상 결과
김은주⋅구성현⋅이광자⋅이규원⋅박영정
Cheil Eye Hospital, Daegu, Korea
Abstract
PURPOSE
To report the clinical results after the implantation of intrastromal corneal ring segments (Intacs(R)) by manual tunnel creation for the correction of keratoconus. METHODS: This retrospective case series was comprised of 10 eyes of 8 consecutive keratoconic patients. Visual acuity, refractive outcome, keratometric values, anterior chamber depth, central corneal thickness, and endothelial cell density were evaluated before and at 1 month, 3 months, and 6 months postoperatively. In addition, the implanted ring segment depth was measured by anterior segment optical coherence tomography at postoperative 6 months. Any postoperative complications were also recorded. RESULTS: Visual acuity was improved in 9 out of 10 eyes. Spherical equivalent and keratometric values were decreased in all eyes. There was no significant difference in central corneal thickness, but endothelial cell density and anterior chamber depth were slightly decreased. The depth of ring segments was almost constant at superior, middle, and inferior. There was a single case of descented implanted ring segments and 6 cases of stromal infiltration around ring segments, but visual acuity was unaffected. In addition, 1 case showed implanted ring exposure, thus the superior ring segment was removed at postoperative 4 months. CONCLUSIONS: Intrastromal corneal ring segment implantation (Intacs(R)) by manual tunnel creation appears to be effective in improving the visual acuity and stabilizing corneal refractive power in keratoconic patients.
Key Words: Intacs;Intrastromal corneal ring;Keratoconus;Manual tunnel creation


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
SKY 1004 Building #701
50-1 Jungnim-ro, Jung-gu, Seoul 04508, Korea
Tel: +82-2-583-6520    Fax: +82-2-583-6521    E-mail: kos08@ophthalmology.org                

Copyright © 2024 by Korean Ophthalmological Society.

Developed in M2PI

Close layer
prev next