J Korean Ophthalmol Soc > Volume 53(12); 2012 > Article
Journal of the Korean Ophthalmological Society 2012;53(12):1794-1800.
DOI: https://doi.org/10.3341/jkos.2012.53.12.1794    Published online December 15, 2012.
Modified Surgical Technique for Transscleral Fixation of a Single-Piece Acrylic Intraocular Lens in the Absence of Capsular Support.
Jong Yun Yang, Young Kwang Chu
1The Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, Seoul, Korea.
2Siloam Eye Hospital, Seoul, Korea. docchu@hotmail.com
일체형 아크릴재질의 인공수정체를 이용한 공막봉합 이차 인공수정체 삽입술
양종윤1,2⋅주영광2
The Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine1, Seoul, Korea
Siloam Eye Hospital2, Seoul, Korea
Abstract
PURPOSE
To introduce a new surgical method of transscleral intraocular lens (IOL) fixation using a foldable, single-piece acrylic IOL with 4 loop haptics and to report the surgical results. METHODS: After a single-piece acrylic IOL with 4 loop haptics was injected into the anterior chamber and positioned on top of the iris diaphragm, a 10-0 Prolene STC-6 straight needle and a 27-gauge needle were used to string the prolene thread through the haptic openings from front to back fixating the IOL to the sclera, resulting in a transscleral "1 loop 4 points" fixation. Twenty-eight eyes of 28 patients who had received transscleral fixation via this new technique were retrospectively reviewed. The best corrected vision acuity (BCVA) was measured after a postoperative period of at least 6 months. Intraoperative and postoperative complications were investigated. RESULTS: In 27 out of 28 eyes (96.4%), the postoperative BCVA was better than 0.5 (Snellen chart). The only complication found was 1 case of choroidal detachment (3.6%). CONCLUSIONS: The new transscleral "1 loop 4 points" fixation technique of a foldable, single-piece acrylic IOL in the absence of capsular support is an easy procedure and reduces surgical time and hastens visual rehabilitation due to excellent IOL positioning stability. Additionally, the technique described in the present study may be a safe procedure with minimal complications.
Key Words: Intraocular lens implantation;Scleral fixation


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
SKY 1004 Building #701
50-1 Jungnim-ro, Jung-gu, Seoul 04508, Korea
Tel: +82-2-583-6520    Fax: +82-2-583-6521    E-mail: kos08@ophthalmology.org                

Copyright © 2024 by Korean Ophthalmological Society.

Developed in M2PI

Close layer
prev next