J Korean Ophthalmol Soc > Volume 51(9); 2010 > Article
Journal of the Korean Ophthalmological Society 2010;51(9):1264-1270.
DOI: https://doi.org/10.3341/jkos.2010.51.9.1264    Published online September 15, 2010.
Comparison of Damage Degrees After Corneal Epithelial Debridement Using Different Instruments in Rabbit Eyes.
Ju young Kim, Jong Hyuck Lee, Suk Jun Lee, Ie Na Yoon
1Department of Ophthalmology, Wonju Christian Hospital, Yonsei University Wonju College of Medicine, Wonju, Korea. bswhitey@hanmail.net
2Yonsei Prime Eye Center, Wonju, Korea.
토끼눈에서 기구에 따른 각막상피제거술 후 손상 정도의 비교
김주영1ㆍ이종혁1ㆍ이석준2ㆍ윤이나1
Department of Ophthalmology, Wonju Christian Hospital, Yonsei University Wonju College of Medicine1, Wonju, Korea Yonsei Prime Eye Center2, Wonju, Korea
Abstract
PURPOSE
A corneal epithelial debridement using three different instruments was performed in rabbits, and the rates of corneal epithelium recovery were compared. Additionally, the extent of corneal damage as determined by the scanning electron microscopy was evaluated in each group. METHODS: Nineteen eyes of ten rabbits were classified into three groups according to the instruments used. The corneal epithelial debridement was performed using three different instruments: a Beaver blade (group A), a Bard-Parker blade No.15 (group B) and a dry cotton-tipped ap plicator (group C). After epithelial debridement, each cornea was observed every 24 hours for three days. After completion of the corneal recovery, each cornea was severed along the limbus and observed under the scanning electron microscope. RESULTS: The rate of corneal epithelial healing of the group C (dry cotton-tipped applicator) showed no statistical significance from those of the other groups. However, according to the corneal status observed under scanning electron microscope after debridement, cracks in the corneal surface in portions of group A and B were observed in contrast with no creaks in group C. CONCLUSIONS: Based on these results, corneal epithelial debridement using a cotton-tipped applicator is expected to reduce the occurrence of postoperative corneal complications. Use of a dry cotton-tipped applicator for corneal epithelial debridement in vitreoretinal surgery is suggested.
Key Words: Blade;Corneal epithelial debridement;Cotton tip;Crack;Instrument


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
SKY 1004 Building #701
50-1 Jungnim-ro, Jung-gu, Seoul 04508, Korea
Tel: +82-2-583-6520    Fax: +82-2-583-6521    E-mail: kos08@ophthalmology.org                

Copyright © 2024 by Korean Ophthalmological Society.

Developed in M2PI

Close layer
prev next