J Korean Ophthalmol Soc > Volume 51(10); 2010 > Article
Journal of the Korean Ophthalmological Society 2010;51(10):1392-1397.
DOI: https://doi.org/10.3341/jkos.2010.51.10.1392    Published online October 15, 2010.
Pattern VEP in Adult Amblyopic Patients Requested From Military Service.
Woong Sun Yoo, Yeon Jung Park, Ji Myong Yoo
1Department of Ophthalmology, Gyeongsang National University School of Medicine, Jinju, Korea. yjm@nongae.gsnu.ac.kr
2Gyeongsang Institute of Health Science, Gyeongsang National University, Jinju, Korea.
징병신체검사에서 의뢰된 성인 약시 환자의 무늬시유발전위의 양상
유웅선1ㆍ박연정1ㆍ유지명1,2
Department of Ophthalmology, Gyeongsang National University School of Medicine1, Jinju, Korea Gyeongsang Institute of Health Science, Gyeongsang National University2, Jinju, Korea
Abstract
PURPOSE
To evaluate the pattern VEP in adult amblyopic patients seen in consultation for ophthalmic evaluation as a past of physical examinations for conscription. METHODS: We retrospectively analyzed, 67 men, 20-year-old or older, who had pattern VEP done for the diagnosis of amblyopia from January 2004 to May 2009. P100 latency and P100 amplitude were analyzed. RESULTS: Thirteen patients were non-amblyopic, and 54 patients had amblyopia. Binocular amblyopia and monocular amblyopia were found in 23 and 31 patients, respectively. In the binocular amblyopic patients, four patients were hyperopic, seven patients were myopic, and 12 patients were astigmatic amblyopia. In the monocular amblyopic patients, 15 patients were anisometropic, 12 patients were strabismic, and four patients had organic amblyopia. The value of P100 latency and P100 amplitude were statistically significantly different between non-amblyopic and amblyopic eyes, with check size of 32x32. However, the types of amblyopia among the patients were not different at a statistically significant level. Visual acuity and P100 amplitude were significantly positively correlated. CONCLUSIONS: VEP might be a useful tool for diagnosis of adult amblyopia, especially using a 32x32 check size. This tool may impart the ability to decide relationship between amblyopia and visual acuity by analyzing P100 latency and amplitude values.
Key Words: Adult;Amblyopia;Visual evoked potential (VEP)


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
SKY 1004 Building #701
50-1 Jungnim-ro, Jung-gu, Seoul 04508, Korea
Tel: +82-2-583-6520    Fax: +82-2-583-6521    E-mail: kos08@ophthalmology.org                

Copyright © 2024 by Korean Ophthalmological Society.

Developed in M2PI

Close layer
prev next