Accuracy of the Haigis Formula Based on Axial Length and Anterior Chamber Depth.
Chan Hui Yi, Sung Ho Choi, Eui Sang Chung, Tae Young Chung
Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea. tychung@skku.edu
안구 길이와 전방 깊이에 따른 Haigis 공식의 정확성
이찬희⋅최성호⋅정의상⋅정태영
Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
Abstract
PURPOSE
To evaluate the effect of axial length (AXL) and anterior chamber depth (ACD) on the accuracy of the Haigis formula in comparison to its effect on other 3rd generation IOL power calculations. The possibility of measurement error in ACD using either method was also investigated. METHODS: A study was performed on 137 eyes of 98 patients who underwent cataract surgery in our hospital. AXL and ACD were measured using IOL Master, and IOL power was calculated using the Haigis, SRK/T, Hoffer Q, and Holladay 1 formulas. ACD was also measured using Pentacam. Patients were divided into 3 groups based on ACD and AXL. Mean numeric error and mean absolute error were analyzed 1 month after surgery. RESULTS: Five formulae showed no significant difference in refractive error in the 3 groups based on AXL. In contrast, the Haigis formula showed statistically significant differences in the group with shallow ACD, in which hyperopic shift was also demonstrated. The difference in ACD between using IOL Master and using Pentacam was significant in the shallow ACD group, with IOL Master showing more shallow measurement. However, the other groups based on ACD showed no significant difference in the refractive error from the Haigis formula, and in the difference in ACD between measurements. CONCLUSIONS: Errors in ACD measurement should be taken into consideration for discrepancy between the Haigis formula measurement and other formula measurements. The authors of the present study suggest that ACD-driven refractive error should be considered in determination of IOL.
Key Words: Anterior chamber depth;Axial length;Haigis formula;Intraocular lens power calculation


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
SKY 1004 Building #701
50-1 Jungnim-ro, Jung-gu, Seoul 04508, Korea
Tel: +82-2-583-6520    Fax: +82-2-583-6521    E-mail: kos08@ophthalmology.org                

Copyright © 2024 by Korean Ophthalmological Society.

Developed in M2PI

Close layer
prev next