Comparison of Flap Thickness Measured with Ultrasound Subtraction Method, Direct Method, and Optical Coherence Tomography.
Su Hwan Lee, Joo Eun Lee, Jae Yong Kim, Myung Joon Kim, Hung Won Tchah
Department of Ophthalmology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea. hwtchah@amc.seoul.kr
각막절편 두께 측정법의 비교: 초음파 각막두께측정계의 차감법, 직접측정법과 빛간섭단층촬영계
이수환⋅이주은⋅김재용⋅김명준⋅차흥원
Department of Ophthalmology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
Abstract
PURPOSE
To compare the flap thicknesses measured with the ultrasound (US) subtraction method, the direct method, and optical coherence tomography (OCT) in femtosecond laser-assisted LASIK eyes. METHODS: The present study included 65 eyes of 37 patients who underwent femtosecond laser-assisted LASIK surgery. Flap thickness was measured intraoperatively using the direct and subtraction methods with US pachymetry and postoperatively using anterior segment OCT. Flap thickness measurements were compared among the three methods. RESULTS: There was no significant difference between the flap thickness measured using the US subtraction method and OCT (p = 0.511). The flap thickness values obtained by these two different methods also correlated well with each other (gamma = 0.820, p < 0.001). However, flap thickness measured using the US direct method was significantly different (p < 0.001) with a low agreement value compared to the other two methods. Furthermore, the US direct method showed a lower measurement success rate compared to the US subtraction method (54% vs. 95%). CONCLUSIONS: Flap thickness measured using the US subtraction method and OCT showed different values compared to that measured using the US direct method. Because of the lower measurement success rate and agreement value, the US direct method is not capable of being used in substitute for the US subtraction method.
Key Words: Anterior segment optical coherence tomography;Femtosecond laser;Flap thickness;Ultrasound pachymetry


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
SKY 1004 Building #701
50-1 Jungnim-ro, Jung-gu, Seoul 04508, Korea
Tel: +82-2-583-6520    Fax: +82-2-583-6521    E-mail: kos08@ophthalmology.org                

Copyright © 2024 by Korean Ophthalmological Society.

Developed in M2PI

Close layer
prev next