Journal of the Korean Ophthalmological Society 2005;46(3):442-447.
Published online March 31, 2005.
Normal Retinal Nerve Fiber Layer Thickness in the Peripapillary Region of Koreans Measured by Scanning Laser Polarimeter.
Gi Hyung Kim, Gyoung Hwan Roh
Department of Ophthalmology, Myung Gok Eye Research Institute, College of Medicine, Konyang University, Daejeon, Korea. eyedr00@yahoo.co.kr
주사 레이저 편광측정계에 의한 한국 정상 성인의 망막신경섬유층 두께 분석
김기형,노경환
Department of Ophthalmology, Myung Gok Eye Research Institute, College of Medicine, Konyang University, Daejeon, Korea
Correspondence:  Gi-Hyung Kim, M.D.
Abstract
PURPOSE
To measure normal retinal nerve fiber layer thickness (RNFLT) in the peripapillary region of Koreans using a scanning laser polarimeter, the nerve fiber analyzer (GDx VCC). METHODS: Two hundred ninety-nine eyes of 299 healthy subjects (156 men, 143 women) were recruited for this study. No subject had diabetes mellitus, hypertension, or any other neurologic disorders. All subjects were normal at ophthalmologic examination, which was assessed by slit-lamp biomicroscopy using a 90-diopter lens, Goldmann applanation tonometry, and Humphrey visual field analysis. Using the GDx VCC, we analyzed the mean value of each parameter in GDx VCC (average at global, superior, inferior, superior maximum and inferior maximum) and evaluated the difference between men and women and each decade of age. RESULTS: Mean RNFLT parameters in GDx VCC were global 56.42 +/- 6.84 micrometer, superior 70.51 +/- 8.70 micrometer, inferior 67.55 +/- 9.04 micrometer, superior maximum 83.52 +/- 12.38 micrometer, and inferior maximum 82.64 +/- 12.70 micrometer. The parameters which showed a difference between men and women were superior average and superior and inferior maximum average RNFLT. The superior RNFLT was thicker than the inferior ones. RNFLT was not statistically different in each decade of age. CONCLUSIONS: We can make good use of the normal parameters of GDx VCC in Koreans for early diagnosis and follow-up of glaucoma.
Key Words: GDx VCC;Glaucoma;RNFL thickness;Scanning laser polarimeter


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
SKY 1004 Building #701
50-1 Jungnim-ro, Jung-gu, Seoul 04508, Korea
Tel: +82-2-583-6520    Fax: +82-2-583-6521    E-mail: kos08@ophthalmology.org                

Copyright © 2024 by Korean Ophthalmological Society.

Developed in M2PI

Close layer
prev next