Journal of the Korean Ophthalmological Society 2003;44(5):1023-1028.
Published online May 1, 2003.
Comparison of Optic Disc Measurements between Computer-aided Morphometry and Heidelberg Retina Tomograph.
Hwan Eok Yeo, Ki Bang Uhm, Chul Hong
1Department of Ophthalmology, Hanyang University College of Medicine, Korea. KBUhm@hanyang.ac.kr
2Glaucoma Service, Dr. Hong's Eye Clinic, Korea.
개인용 컴퓨터와 Heidelberg Retina Tomograph로 구한 시신경유두 측정치의 비교
여환억 ( Hwan Eok Yeo ) , 엄기방 ( Ki Bang Uhm ) , 홍철 ( Chul Hong )
Abstract
PURPOSE
To compare optic disc measurements between computer-aided morphometry and Heidelberg Retina Tomograph (HRT). METHODS: For 59 patients with primary open-angle glaucoma and 9 subjects with ocular hypertension, measurements of the optic disc area and neuroretinal rim area were obtained using our computer-aided morphometric techniques and the HRT. RESULTS: The mean optic disc areas measured with the HRT was smaller than those with the computer-aided techniques (p=0.02). Rim area and rim area to disc area were significantly (p
Key Words: Computer-aided morphometry;Heidelberg Retia Tomograph;Neuroretinal rim;Optic disc