Journal of the Korean Ophthalmological Society 2003;44(10):2235-2241.
Published online October 1, 2003.
The Analysis of Refractive Errors of AMO Array(R) Multifocal Intraocular Lens with SRK II Formula.
Seon Jeong Kim, Seon Jae Cho, Jun Seok Tae, Moo Il Lee, Dae Hyun Kim, Moon Joo Lee, Jung Hyub Oh
1Department of Ophthalmology, Inha University College of Medicine, Korea. jhoh9707@hanmail.net
2Tae Eye Clinic, Pyung-chon, Kyungui-do, Korea.
3KangNam-Balgeun Eye Clinic, Seoul, Korea.
4Deasung Yunsei Eye Clinic, Buchon, Kyungui-do, Korea.
5Lee Eye Clininc, Gu-Ri, Kyungui-do, Korea.
SRK 2 공식으로 AMO Array(R) 다초점 인공수정체 삽입시 굴절오차 분석
김선정 ( Kim Seon Jeong ) , 조선재 ( Jo Seon Jae ) , 태준석 ( Tae Jun Seog ) , 이무일 ( Lee Mu Il ) , 김대현 ( Kim Dae Hyeon ) , 이문주 ( Lee Mun Ju ) , 오중협 ( O Jung Hyeob )
Abstract
PURPOSE
To evaluate the accuracy of the SRK II formula for the AMO Array(R) multifocal intraocular lens (Array lens) power calculation according to axial length. In case of refractive error more than +/- 1.0 diopter (D), we compared the accuracy of the SRK II with that of other formulas. METHODS: Participants were 178 eyes (142 patients) received the Array lens. These were divided into 3 subgroups based on axial length. Group I had 21 eyes of short axial length (less than 22.0 mm). Group II had 133 eyes of average axial length (more than 22.0mm below 24.5mm). Group III had 24 eyes of long axial length (more than 24.5mm). The difference between preoperative predicted refractive value and postoperative manifest refractive value were calculated. We compared the accuracy of the SRK II and that of SRK/T, Holladay formulas in case of refractive error more than +/- 1.0D. RESULTS: Three eyes (14.2%) in Group I, 14 eyes (10.5%) in group II and 15 eyes (62.5%) in Group III showed refractive errors more than +/- 1.0D. Fifteen eyes (62.5%) in Group III were significantly reduced to 7 eyes (29.1%) with using SRK/T, Holladay formulas. CONCLUSIONS: SRK II formula had better predictive accuracy in axial length less than 24.5mm with Array lens. But it is better to apply SRK/T or Holladay formulas when axial length is more than 24.5mm.
Key Words: AMO Array(R) multifocal IOL;Holladay;Refractive error;SRK II;SRK/T


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
SKY 1004 Building #701
50-1 Jungnim-ro, Jung-gu, Seoul 04508, Korea
Tel: +82-2-583-6520    Fax: +82-2-583-6521    E-mail: kos08@ophthalmology.org                

Copyright © 2024 by Korean Ophthalmological Society.

Developed in M2PI

Close layer
prev next