Journal of the Korean Ophthalmological Society 2001;42(8):1172-1177.
Published online August 1, 2001.
The Effect of a 5-0 Prolene Ligation Around the Ahmed Glaucoma Valve Tube on the Postoperative Hypotony.
Jae Wook Yang, Young Il Kim, Chang Won Gi
1Department of Ophthalmology, Busan Paik Hospital, Inje University Medical College, Busan, Korea.
2Department of Ophthalmology, Samsung Medical Center, College of Medicine, Sungkyunkwan University, Seoul, Korea.
Ahmed Glaucoma Valve 삽입술에서 술 후 저안압의 예방을 위한 5-0 Prolene 실리콘관 결찰법의 효과
양재욱(Jae Wook Yang),김영일(Young Il Kim),기창원(Chang Won Gi)
Abstract
PURPOSE
To evaluate the efficacy and safety of 5-0 prolene ligation around the Ahmed glaucoma valve tube to prevent the postoperative hypotony and flat anterior chamber. METHODS: Medical records of twenty one eyes of 20 patients those had got Ahmed valve implant surgery with temporary ligation of the tube with 5-0 prolene were retrospectively evaluated for efficacy of the pressure control and complications before and after the remove of the ligation suture. RESULTS: Preoperative intraocular pressure(IOP) was 46.1+/-9.1 mmHg. The ligation suture was removed at 2.8+/-1.5 postoperative day. Postoperative IOP before the removal of the suture was 24.8+/-15.4 mmHg at the day of removal. After removal of the ligation suture, the IOP decreased to 15.6+/-5.9 mmHg and 12.2+/-4.2 mmHg at one day and 12 weeks after the removal respectively. Complications before the removal of the ligation suture were mild hyphema and corneal edema, developed in one eye each. After the removal, shallow anterior chamber and choroidal detachment was developed in one eye. CONCLUSIONS: Although the efficacy of the temporary ligation of the tube in Ahmed valve implant surgery in controlling the IOP was similar to that of conventional Ahmed valve implant surgery without ligation, the early postoperative complications associated with the overfiltration appeared to be less frequent than conventional Ahmed valve implant surgery.
Key Words: Ahmed glaucoma valve implant;5-0 prolene ligation;Postoperative hypotony


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
SKY 1004 Building #701
50-1 Jungnim-ro, Jung-gu, Seoul 04508, Korea
Tel: +82-2-583-6520    Fax: +82-2-583-6521    E-mail: kos08@ophthalmology.org                

Copyright © 2024 by Korean Ophthalmological Society.

Developed in M2PI

Close layer
prev next