Journal of the Korean Ophthalmological Society 1993;34(5):376-383.
Published online May 1, 1993.
Effect of Distances Between Corneoscleral Limbus and Transscleral Sutures on Vision and Refraction in Eyes with Posterior Chamber Intraocular Lens Implanted by Transscleral Suture Fixation.
Jin Ho Chang, Jin Hak Lee
Department of Ophthalmology, College of Medicine, Seoul National University, Seoul, Korea.
공막 고정에 의한 인공수정체 삽입술 환자에 있어서의 봉합사와 각공막윤부간 거리
장진호(Jin Ho Chang),이진학(Jin Hak Lee)
Abstract
We retrospectively analyzed the correlation between location of transscIeral sutures and the postoperative vision, refraction, anterior chamber depth (ACD) with linear regression, in eyes with posterior chamber intraocular lenses (PCL's) implanted by transscleral suture fixation. The suture to limbus distances at 12 and 6 o'clock position measured in average 2.4mm and 1.7mm respectively. The location of the sutures had no statistically significant relationship with postoperative vision, spherical equivalent, astigmatism, ACD.
Key Words: Astigmatism;Posterior chamber intraocular lens;Suture to limbus distance;Transscleral suture fixation;Vision