Journal of the Korean Ophthalmological Society 1988;29(2):353-362.
Published online February 1, 1988.
The Effect of Combined Application of Argon and Nd-YAG Laser on Iridectomy in Rabbits.
Chan Park, Sang Wook Rhee
Department of Ophthalmology, Catholic University, Medical College, Seoul, Korea.
가토안의 홍채절제술에 대한 Argon 레이저 및 Nd - YAG 레이저 병합조사의 효과
박찬(Chan Park),이상욱(Sang Wook Rhee)
Abstract
Recently iridectomy using argon or Nd-YAG laser to treat narrow angle glaucoma has become popular, and is now a procedure of choice over the standard surgical technique. However, shock wave of Nd-YAG laser causes hemorrhage in almost all cases and high energy level of Nd-YAG laser, which is required for iridectomy, causes injuries to the lens and cornea. Furthermore, there is a tendency toward closure of the iridectomy site after argon laser application. We performed iridectomies by combined application of argon and Nd-YAG laser in pigmented rabbits to improve iris bleeding, iridectomy patency, and lens and corneal damage. The iridectomy patency and the lens and corneal damage were examined with scanning electron microscope. The rabbits that underwent laser iridectomies with only Nd-YAG laser were used as a control group. The following results were obtained: 1. The bleeding rate of the iridectomy in the combined application group was 2.4% and in the control group 98.8% proving the combined application of both lasers to be higly effective. 2. In the experimental group, the patency rate of iridectomy was 33.3% at the energy level of 1 mJ, 66.6% at 2 mJ, 83.3% at 4 mJ, and 6 mJ, respectively. In the control group, the patency rate of iridectomy was 33.3% at the energy level of 4 mJ, 63.6% at 6 mJ, 83.3% at 8 mJ, respecively. At the same energy level, the experimental group showed a higher rate of patency than the control group. 3. In both experimental and control groups, the lens damage was noted at the energy level of 6 mJ or higher. The lens was not affected by lower energy Nd-YAG laser. 4. In the experimental and control groups, the corneal damage was observed at the energy level of 8 mJ or higher. The cornea was not affected by low energy Nd-YAG laser. Based on the above results, it can be concluded that laser iridectomy by combined application of argon and Nd-YAG lasers results in a lower rate of bleeding, a higher rate of patency, and less damage to the lens and cornea as compared with iridectomy performed by Nd-YAG laser only.


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
SKY 1004 Building #701
50-1 Jungnim-ro, Jung-gu, Seoul 04508, Korea
Tel: +82-2-583-6520    Fax: +82-2-583-6521    E-mail: kos08@ophthalmology.org                

Copyright © 2024 by Korean Ophthalmological Society.

Developed in M2PI

Close layer
prev next