Journal of the Korean Ophthalmological Society 1989;30(4):527-533.
Published online April 1, 1989.
The Effect of Healon(R) and Metrol(R) on Cornea and Intraocular Pressure in Extracapsular Cataract Extraction with Posterior Chamber Lens Implantation.
Sang Wook Rhee, Dong Ho Youn, Sung Kun Chung, Dong Gyu Choi
1Department of Ophthalmology, Catholic University Medical College, Seoul, Korea.
2Department of Ophthalmology, College of Medicine, Seoul National University, Seoul, Korea.
백내장 낭외적출 및 후방 인공수정체 삽입후 Healon(R) 과 Metrol(R) 이 각막 및 안압에 미치는 영향
이상욱(Sang Wook Rhee),윤동호(Dong Ho Youn),최동규(Dong Gyu Choi),정성근(Sung Kun Chung)
Abstract
The aim of this study is to evaluate the effect of viscoelastic substance on corneal thickness, corneal endothelium and intraocular pressure by measuring corneal thickness, corneal endothelial cell density and intraocular pressure in extracapsular cataract extraction with posterior chamber lens implantation. The study comprised of 50 patients, divided into two groups: extracapsular cataract extraction with posterior chamber lens implantation using Healon(R) or 2% methylcellulose(Metrol(R)). The txtracapsular cataract extraction was done by irrigation and aspiration technique and the posterior chamber lens was implanted into posterior chamber. The corneal thickness and endothelial cell density were measured preoperatively and at 6 weeks of postoperative period: intraocular pressure was measured preoperatively and at 24 hours of postoperative preiod. The results were as follows: 1. The preoperative corneal thickness, endothelial cell density and intraocular pressure were 499 +/- 34 micrometer, 2523 +/- 388 cells/mm2 and 15.9 +/- 2.4mmHg in average respectively. 2. The postoperative corneal thickness with Healon(R) was 501 +/- 42 micrometer, and with Metrol(R) was 491 +/- 28 micrometer. There was no significant difference between Healon(R) used and Metrol(R) used group(p<0.05). 3. The loss of endothelial cell with Healon(R) was 10.7%, and with Metrol(R) was 17.1%. The endothelial cell loss was lower in Healon(R) used group than that of Metrol(R) group. 4. The intraocular pressure with Healon(R) was 14.6 +/- 3.9mmHg, and with Metrol(R) was 12.3 +/- 4.4mmHg. There was no significant difference between Healon(R)-used and Metrol(R)-used group(p<0.05).
Key Words: corneal thickness;corneal endothelial density;Healon(R);intraocular pressure;Metrol(R)


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
SKY 1004 Building #701
50-1 Jungnim-ro, Jung-gu, Seoul 04508, Korea
Tel: +82-2-583-6520    Fax: +82-2-583-6521    E-mail: kos08@ophthalmology.org                

Copyright © 2024 by Korean Ophthalmological Society.

Developed in M2PI

Close layer
prev next