J Korean Ophthalmol Soc > Volume 57(3); 2016 > Article
Journal of the Korean Ophthalmological Society 2016;57(3):405-412.
DOI: https://doi.org/10.3341/jkos.2016.57.3.405    Published online March 15, 2016.
Comparison of the Visual Outcomes after Cataract Surgery with Implantation of a Bifocal and Trifocal Diffractive Intraocular Lens.
Sung Yu, Yong Il Kim, Sang Won Ha, Gwang Ja Lee, Kyoo Won Lee, Young Jeung Park
Cheil Eye Hospital, Daegu, Korea. eyepark9@naver.com
회절성 이중 다초점 인공수정체와 회절성 삼중 다초점 인공수정체의 임상 결과 비교
유 성⋅김용일⋅하상원⋅이광자⋅이규원⋅박영정
제일안과병원
Abstract
PURPOSE
To evaluate and compare visual outcomes and optical quality after implantation of a bifocal (Acrysof ReSTOR® SN6AD1) or trifocal (AT LISA® tri 839MP) diffractive intraocular lens (IOL). METHODS: Fifty-one eyes of 43 patients undergoing cataract surgery were enrolled and assigned to one of two groups: the trifocal group, comprising 24 eyes implanted with the trifocal diffractive IOL (AT LISA® tri 839MP), and the bifocal group, comprising 27 eyes implanted with the bifocal diffractive IOL (Acrysof ReSTOR® SN6AD1). Visual acuity (distant, intermediate, and near vision) and refractive postoperative outcomes were evaluated at one and three months postoperatively. Measurements of optical quality (using OQAS II®), contrast sensitivity (using CGT-2000®), automated visual field examination, and evaluation of defocus curve were performed three months postoperatively. RESULTS: No statistically significant differences between the two groups were found in three-month postoperative distant and near (40 cm) visual acuities and optical quality. However, intermediate (63 cm, 80 cm, and 100 cm) visual acuities were significantly better in the trifocal group. Distant contrast sensitivity (5 m) under mesopic conditions was significantly better with the bifocal lens, whereas near contrast sensitivity (30 cm) under mesopic and scotopic conditions was significantly better with trifocal lens. There was no statistical difference between the groups under photopic conditions. In the defocus curve, the visual acuity was significantly better at intermediate distance in the trifocal group. CONCLUSIONS: Trifocal diffractive IOLs provide significantly better intermediate vision than bifocal IOLs, with equivalent postoperative levels of distant and near vision and ocular optical quality. Further, they provide better near contrast sensitivity under scotopic condition compared to diffractive bifocal IOLs.
Key Words: Bifocal;Cataract;Diffractive;Multifocal intraocular lens;Trifocal


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
SKY 1004 Building #701
50-1 Jungnim-ro, Jung-gu, Seoul 04508, Korea
Tel: +82-2-583-6520    Fax: +82-2-583-6521    E-mail: kos08@ophthalmology.org                

Copyright © 2024 by Korean Ophthalmological Society.

Developed in M2PI

Close layer
prev next