J Korean Ophthalmol Soc > Volume 53(12); 2012 > Article
Journal of the Korean Ophthalmological Society 2012;53(12):1749-1755.
DOI: https://doi.org/10.3341/jkos.2012.53.12.1749    Published online December 15, 2012.
Effect of Preoperative Crystalline Lens Rise on Vaulting after Implantable Collamer Lens Implantation.
Ae Young Kwak, Ik Hee Ryu, Jin Kook Kim, Tae Im Kim, Byoung Jin Ha
1The Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, Seoul, Korea.
2Siloam Eye Hospital, Seoul, Korea.
3Eyenu Eye Clinic, Seoul, Korea.
4BS Eye Center, Seoul, Korea.
5BGN Eye Clinic, Seoul, Korea. nairwiny@naver.com
술 전 Crystalline Lens Rise가 안내후방인공수정체 삽입술 후 Vaulting에 미치는 영향
곽애영1,2⋅류익희3⋅김진국4⋅김태임1⋅하병진5
The Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine1, Seoul, Korea
Siloam Eye Hospital2, Seoul, Korea
Eyenu Eye Clinic3, Seoul, Korea
BS Eye Center4, Seoul, Korea
BGN Eye Clinic5, Seoul, Korea
Abstract
PURPOSE
To evaluate the parameters affecting vaulting and correlation between preoperative crystalline lens rise and vaulting after implantable collamer lense (ICL) implantation. METHODS: A total of 53 eyes of 34 patients who underwent ICL implantation were examined retrospectively. White-to-white (WTW) and anterior chamber depth (ACD) were obtained from scanning topography (ORB scan) before surgery. Preoperative crystalline lens rise (CLR) and vaulting at 6 months after ICL implantation were measured using anterior segment optic coherence tomography (AS-OCT). Multiple regression analysis was performed to evaluate the factors affecting central vaulting. RESULTS: The mean preoperative crystalline lens rise was -120 +/- 219 microm, and mean central vaulting 6 months after surgery was 544 +/- 175 microm. Preoperative SE, WTW, ACD, and CLR were significantly correlated with vaulting at 6 months after surgery. With the use of meaningful variables, multiple regression analysis showed that CLR, WTW, ACD and SE, in that order of influence, had significant effects on vaulting and the multiple regression equation was obtained as follows: Vaulting (microm) = (160.913 x ACD (mm)) + (170.134 x WTW (mm)) + (-0.338 x CLR (microm)) + (-23.783 x SE (D)) - 2250.184. CONCLUSIONS: CLR had a stronger influence on vaulting after ICL implantation than the previously proven parameters: WTW, ACD, and SE. In addition to WTW, ACD and SE, CLR should also be considered a new criterion for estimating vaulting after ICL implantation.
Key Words: Anterior chamber depth;Crystalline lens rise;Implantable contact lens;Vaulting;White-to-white


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
SKY 1004 Building #701
50-1 Jungnim-ro, Jung-gu, Seoul 04508, Korea
Tel: +82-2-583-6520    Fax: +82-2-583-6521    E-mail: kos08@ophthalmology.org                

Copyright © 2024 by Korean Ophthalmological Society.

Developed in M2PI

Close layer
prev next