The Comparison of Viscosity-dependent Distribution of Tear Film after Dropping of Three Artificial Tears.
Joon Il Hyun, Eung Kweon Kim, Jae Bum Lee
The Institute of Vision Research, Department of Ophthalmology, College of Medicine, Yonsei University, Youngdong Severance Hospital.
3 가지 인공누액 점안 후 점탄성에 의한 눈물층 분포 비교
현준일(Joon Il Hyun),김응권(Eung Kweon Kim),이재범(Jae Bum Lee)
Abstract
We intended to evaluate the viscosity-dependent distribution of tear film after dropping of three artificial tears with different viscosity. We measured the corneal thickness including tear film thickness after dropping of Optagent[Povidon iodide 2%; viscosity: 1.5millimeter2/sec], Tears naturale free[hydroxypropyl methylcellulose 0.3%, dextran 0.1%;6.4 millimeter2/sec], Lacura [sodium hyaluronate 0.1%;4.6 millimeter2/sec]in 12 adult men and women without dry eye by optical beam scanning differential pachymetry of Orbscan topography. 1 minute after dropping, the thickness of 3 millimeter superior and inferior to center of cornea increased respectively 4.1 +/-0.4 micrometer, 0.4 +/-0.1micrometer[p=0.014]in Optagent, 2.4 +/-0.3 micrometer, 2.3 +/-0.2 micrometer[p=0.425]in Tears naturale free and 2.5 +/-0.5 micrometer, 2.0 +/-0.2 micrometer[p=0.126]in Lacure. 10 minute after dropping, the thickness of 3 millimeter superior and inferior to center of cornea increased respectively 2.7 +/-0.3 micrometer, 0.3 +/-0.1 micrometer[p=0.025]in Optagent, 1.7 +/-0.2 micrometer, 1.6 +/-0.2 micrometer[p=0.326]in Tears naturale free and 1.4 +/-0 .4 micrometer, 1.2 +/-0.2 micrometer[p=0.237]in Lacura. In conclusion, the artificial tears with relatively high viscosity dstributed evenly along the corneal surface after dropping, but those with relatively low viscosity distributed mainly superior to center of cornea with statistical significance. So when treating of corneal lesion in dry eye, we think that artificial tears with proper viscosity will be needed according to the location of the lesion.
Key Words: Artificial tear;Dry eye;Tear film thickness;Viscosity
TOOLS
METRICS Graph View
  • 562 View
  • 10 Download
Related articles


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
SKY 1004 Building #701
50-1 Jungnim-ro, Jung-gu, Seoul 04508, Korea
Tel: +82-2-583-6520    Fax: +82-2-583-6521    E-mail: kos08@ophthalmology.org                

Copyright © 2024 by Korean Ophthalmological Society.

Developed in M2PI

Close layer
prev next