Three-year follow-up of Clinical Results after SI-30NB Intraocular Lens Implantation Through Temporal Clear Corneal Incision. |
Min Cheol Seong, Choun Ki Joo, Hye Bin Yim |
Department of Ophthalmology, Kangnam St.Mary's Hospital, College of Medicine, The Catholic University of Korea. |
이측부 투명각막 절개창을 통한 SI - 30NB 인공수정체삽입후 3 년간의 임상성적 |
성민철(Min Cheol Seong),주천기(Choun Ki Joo),임혜빈(Hye Bin Yim) |
|
|
Abstract |
We examined the clinical results of silicone IOL[SI-30NB]for 3 years or more. A total of 50 eyes underwent phacoemulsification and foldable silicone posterior chamber lens implantation through 3.2 millimeter temporal clear corneal incision. Preoperative and post-operative intraocular pressure, visual acuity, corneal astigmatism and complications were evaluated. More than 94%of all cases showed best corrected visual acuity better than 20/40 and intraocular pressure was decreased for 2 months. At 1 day after operation, mean surgically induced astigmatism was minimal[0.64 +/-1.42]and recovered fast. Posterior capsular opacity was found in 26%;however, Nd-YAG laser capsulotomy was performed in 18%. In conclusion, foldable silicone lens implantation through 3.2 millimetertemporal clear corneal incision revealed a low incidence of complication, minimally induced astigmatism, and rapid visual rehabilitation. |
Key Words:
Complication;Silicone IOL[SI-30NB];Temporal clear corneal incision |
|